Understanding The Trap Description

The following table lists in alphabetical order each line item that may appear in the trap description.
Table 1. Trap Description
Description Line Item Explanation
Action performed was: <Action> Specifies the automatic server recovery action that was performed, for example:

Action performed was: Power cycle

Action requested was: <Action> Specifies the user initiated host control action that was requested, for example:

Action requested was: Reboot, shutdown OS first

Additional details: <Additional details for the events> Specifies possible additional details about the specified device, for example:

Additional details:

Memory device: DIMM_1A Serial number: 11111111

Memory device: DIMM_1B Serial number: 22222222

<Additional power supply status information> Specifies any additional power supply information pertaining to the event, for example:

Power supply input AC is off, Power supply POK (power OK) signal is not normal, Power supply is turned off

Battery sensor status: <status> Specifies the status reported by the battery sensor, for example:

Battery sensor status: Predictive failure

Chassis intrusion state: <Intrusion state> Specifies the chassis intrusion state (open or closed), for example:

Chassis intrusion state: Open

Chassis location: <Name of chassis> Specifies the name of the chassis that generated the message, for example:

Chassis location: Main System Chassis

Configuration error type: <type of configuration error> Specifies the type of configuration error that occurred, for example:

Configuration error type: Revision mismatch

Current sensor value (in Amps): <Reading> Specifies the current sensor value in amps, for example:

Current sensor value: 7.853

Date and time of action: <Date and time> Specifies the date and time that an automatic server recovery action was performed, for example:

Date and time of action: Fri May 30 23:55:44 2003.

Description: <Description of event> Specifies the description of the event that occurred, for example:

Description: Chipset Err: Critical Event sensor, front panel NMI / diagnostic interrupt was asserted.

Device location: <Location in chassis> Specifies the location of the device in the specified chassis, for example:

Device location: Mem Card A

Discrete current state: <State> Specifies the state of the current sensor, for example:

Discrete current state: Good

Discrete temperature state: <State> Specifies the state of the temperature sensor, for example:

Discrete temperature state: Good

Discrete voltage state: <State> Specifies the state of the voltage sensor, for example:

Discrete voltage state: Good

Fan sensor value: <Reading> Specifies the fan speed in revolutions per minute (RPMs) or On/Off, for example:

Fan sensor value (in RPM): 2600

Fan sensor value: Off

Log type: <Log type> Specifies the type of hardware log, for example:

Log type: Embedded Server Management (ESM)

Memory device bank location: <Bank name in chassis> Specifies the name of the memory bank in the system that generated the message, for example:

Memory device bank location: Bank_1

Memory device location: <Device name in chassis> Specifies the location of the memory module in the chassis, for example:

Memory device location: DIMM_A

Number of devices required for full redundancy: <Number> Specifies the number of power supply or cooling devices required to achieve full redundancy, for example:

Number of devices required for full redundancy: 4

Peak value (in Watts): <Reading> Specifies the peak value in Watts, for example:

Peak value (in Watts): 125

Possible memory module event cause: <list of causes> Specifies a list of possible causes for the memory module event, for example:

Possible memory module event cause: Single bit warning error rate exceeded

Single bit error logging disabled

Power Supply type: <type of power supply> Specifies the type of power supply, for example:

Power Supply type: VRM

Pre-failure state was: <State> Specifies the status of the previous memory message, for example:

Pre-failure state was: Failed

Previous redundancy state was: <State> Specifies the status of the previous redundancy message, for example:

Previous redundancy state was: Lost

Previous state was: <State> Specifies the previous state of the sensor, for example:

Previous state was: OK (Normal)

Processor sensor status: <status> Specifies the status of the processor sensor, for example:

Processor sensor status: Configuration error

Redundancy unit: <Redundancy location in chassis> Specifies the location of the redundant power supply or cooling unit in the chassis, for example:

Redundancy unit: Fan Enclosure

SD card device type: <Type of SD card device> Specifies the type of SD card device, for example:

SD card device type: Hypervisor

SD card state: <State of SD card> Specifies the state of the SD card, for example:

SD card state: Present, Failed

Sensor location: <Location in chassis> Specifies the location of the sensor in the specified chassis, for example:

Sensor location: CPU1

Temperature sensor value (in degrees Celsius): <Reading> Specifies the temperature in degrees Celsius, for example:

Temperature sensor value (in degrees Celsius): 30

Voltage sensor value (in Volts): <Reading> Specifies the voltage sensor value in volts, for example:

Voltage sensor value: 1.693


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?